Thermal modelling and testing services
BRE supports industry to achieve good thermal performance in buildings through publications, consultancy and research and provides services to clients seeking advice on building design and regulatory requirements.
Thermal modelling
Building regulations require that thermal bridging be taken into account in SAP and SBEM calculations. The junctions that need to be accounted for include wall-floor junctions, wall-roof junctions, lintels, jambs, cills, intermediate floors, balconies, corners, party walls and other significant junctions. Their effects are expressed in terms of Ψ-values, or linear thermal transmittance values, and, unless they are recognised Accredited Details, they should be evaluated using thermal simulation software, following agreed conventions and standards.
The Certified Thermal Details and Products Scheme provides independently assessed thermal junction details.
BRE Scotland specialise in undertaking analysis of the thermal performance of buildings, building components, junctions, thermal bridge analysis and associated services leading to legislative compliance and improved energy performance calculations.
Conventions for U-value calculations
(BR 443, 2006 Edition)
There are various thermal standards dealing with the calculation of U-values of building elements. The conventions provide guidance on the use of the standards, indicating the methods of calculation that are appropriate for different constructional types, providing additional information about using the methods and providing data relevant to typical UK constructions.
The U-value conventions were original published in 2002 and the 2006 edition is an update which provides additional information and reflects changes in the underlying British Standards. It can be downloaded as a PDF using the link on the right and it is also available from BRE Bookshop.
In-situ U-value Measurement
A U-value can be established by several theoretical calculation methods described in the BRE publication “Conventions for U-value calculations” and the U-value calculator software available from BRE Bookshop.
In existing dwellings theoretical evaluation of the thermal resistance (R value) or thermal transmittance (U-value) can be difficult for the following reasons:
Materials traditionally used in buildings are not homogeneous and their thermal conductivity values are not always available,
Establishing the exact dimensions of layers of materials require destructive methods which may be not possible in the case of existing dwellings.
This document describes an alternative method of establishing U-values of walls given in BS ISO 9869. The procedure applies only where a defined number of measurements are undertaken for a development at different times to calculate an average U-value figure.
This method can be applicable of establishing representative U-values of walls for wider developments assuming that measurements and analysis are carried out in accordance with BS ISO 9869. It should be remembered that it may lead to long periods of measurement and may give erroneous results in certain cases. Note that this method would not be suitable for establishing U-values for a single dwelling for the purposes of EPC.
BRE publications
Conventions for U-value calculations
U-value calculator
SAP assessment procedure 2009
Updates to BR 497
What is thermal bridging and how can thermal modelling help?
Thermal bridging occurs when part of a construction transfers heat more readily than surrounding areas, typically at junctions or connections. Thermal bridging contributes to heat loss in buildings. Non-repeating bridges from junctions are represented by psi-values (ψ, pronounced ‘sigh’) in energy calculations. As buildings become more insulated, thermal bridging can contribute to a higher proportion of the overall heat loss. It can also lead to concentrated cold spots and risk of internal surface condensation. Quantifying heat loss and taking steps to reduce bridging therefore helps reduce energy demand, but can also improve comfort and reduce risk of condensation occurring.
Accurately modelling junctions typically provides psi-values that are much improved over default values that would otherwise be used in calculations within compliance tools (e.g. SAP or SBEM). Calculating bespoke thermal bridging psi-values can therefore offer a cost-effective way of improving energy calculations, compared to the cost of applying additional physical improvements to buildings as an alternative method of meeting improved standards.
Thermal modelling is also used to derive U-values for some complex, non-homogeneous constructions, façade systems, and window frames when they cannot be calculated by simplified methods.
BRE’s thermal modelling services
BRE offer 2D and 3D thermal modelling of project-specific junctions/ constructions, from simple through to highly complex scenarios, calculated in accordance with conventions (i.e. BRE report BR 497, ‘Conventions for calculating linear thermal transmittance and temperature factors’) and relevant British, European and International standards.
We can provide:
- Psi-values (ψ) for linear junctions.
- U-values for complex constructions, including framing systems, curtain walling, windows.
- Chi-values (χ, pronounced ‘kite’ without the ‘t’) for point thermal bridges, such as fixings and connections. These can also be calculated as a correction factor to a U-value.
- Surface temperature factor (f) as an indication of potential surface condensation risk
Our experienced modellers can also identify and advise on potential opportunities for improving junctions/ constructions to reduce heat loss in buildings.
We can provide thermal bridging values applicable to Building Regulations of the UK’s devolved nations, or to the Passivhaus standard for use in PHPP (Passivhaus Planning Package), as required.
Thermal modelling is typically associated with new construction. However, we also offer modelling for retrofit of existing buildings, where risk of internal surface condensation at junctions can be high, and potentially contribute to mould growth and associated health impacts. This is discussed in more detail in the BRE publication FB61, ‘Reducing thermal bridging at junctions when designing and installing solid wall insulation’.
In addition, BRE Global operates the Certified Thermal Details and Products Scheme and associated online library, providing independent third party certification of standard junctions/ constructions for product and system manufacturers, which may be applied to construction projects that utilise certified products.
In-situ U-value measurement services
U-values represent the thermal transmittance of a building element e.g. wall, roof, floor or window and provide an indication of the effectiveness of an element at resisting the passage of heat. U-values are calculated in accordance with conventions and standards for new elements. However, for existing elements that have been subject to ageing and weathering, reference values for the conductivity of various materials within a construction may not be representative of the actual materials.
BRE offers in-situ measurement of U-values of walls according to the BS ISO 9869-1 methodology. This can be useful to understand the existing thermal performance of walls and to support retrofit decisions, such as the level of insulation required to meet target U-values.
U-value measurement is generally carried out during colder weather. This ensures that an appropriate temperature gradient can be maintained between the internal and external environments either side of the test wall without the need for the internal space to be heated beyond a typically comfortable range. However, there are some situations where tests may be carried out during warmer weather where internal temperatures can be elevated appropriately. While it is theoretically possible to obtain data to inform U-value measurements within 3 days via the BS ISO 9869-1 method, running the testing for a longer period of 1 to 2 weeks is generally preferable.