SAP 10 - FAQs
Introduction
Why do we need energy assessment calculation methodologies for homes?
Standardised energy assessment calculation methodologies provide a consistent way to estimate and compare how much energy a home would use, its projected carbon emissions and overall energy efficiency.
A standardised assessment provides the underpinnings to regulation and policy particularly relating to climate goals, heat decarbonisation, fuel poverty, energy cost savings, market transparency and energy efficiency improvements.
The Standard Assessment Procedure (SAP) is the energy assessment calculation methodology for homes that is recognised by UK government and governments of devolved nations. UK government intends to replace SAP with the Home Energy Model (HEM), more details can be found here.
For information about non-domestic buildings national calculation methodology please visit; UK NCM.
The SAP methodology underpins two main regulations:
- Energy Performance of Buildings (England and Wales) Regulations 2012 which mandates the provision of Energy Performance Certificates (EPC)s.
- Approved Document L which supports Part L of Schedule 1 to the Building Regulations 2010.
Standardised methodologies are not intended to match actual energy performance or carbon emissions for buildings due to the assumptions made in them, particularly around occupancy and weather.
SAP and RdSAP
Generally, SAP (Standard Assessment Procedure) is suitable for new builds, conversions, and major extensions (see definitions in Approved Document L) while RdSAP (Reduced Data Standard Assessment Procedure) is used for existing properties. RdSAP was formerly published in Appendix S: Reduced Data SAP for existing dwellings of the SAP specification. It is now produced in a separate document.
The key difference is that SAP involves detailed construction information, whereas RdSAP uses a simplified set of data combined with scientific assumptions for surveys where full construction details are not known. RdSAP is a translation from reduced data to the full SAP dataset, and both use the same core methodology. There are different versions of SAP and RdSAP, the most recent versions can be found here.
An Energy Efficiency Rating (EER) or SAP score is a rating for ranking a dwelling's energy performance, calculated on a scale of 1 to 100+ which is accompanied by a letter from A to G on an EPC. A higher score indicates a more energy-efficient home with lower running costs. The score is calculated based on factors like the building's construction, heating and lighting systems, ventilation, and use of renewable technologies, including set occupancy calculations but it does not account for occupant specific consumption such as cooking or appliance use.
Part L
Part L of the Building Regulations (England) is set out in Approved Document L1 and deals with the conservation of energy and greenhouse gas emissions associated with dwellings (or non-domestic buildings for Approved Document L2). It sets the minimum energy efficiency standards that all new dwellings must meet.
Part L is designed to ensure buildings:
Are more efficient to heat, cool, light, and heat water so that occupants can have lower bills.
Have better insulation and thermal performance to ensure comfort and health.
Reduce carbon emissions in line with UK net zero targets.
MEES
Minimum Energy Efficiency Standards (MEES) are UK regulations requiring landlords to ensure their privately rented properties have an Energy Performance Certificate (EPC) rating of E or above, meaning properties with an F or G rating cannot be let. These standards, which also aim to increase the overall energy efficiency of private rentals to EPC Band C by 2030, came into force for existing tenancies in April 2020. Landlords may be subject to financial penalties for non-compliance and can apply for valid exemptions, such as the "7-year payback" exemption. Further guidance can be found here: Domestic private rented property: minimum energy efficiency standard - landlord guidance - GOV.UK.
Fuel prices
Fuel prices in SAP are calculated using a standardised methodology rather than being based on real‑time market rates. They are specified in Table 12 of the relevant SAP methodology document. All prices are denoted in a pence‑per‑kWh equivalent so that different fuels can be compared on a consistent basis. Some fuels also include a standing charge.
There are two variants of fuel costs used in the SAP methodology:
- Fixed costs (‘Table 12’) which are only updated for every methodology update, and
- EPC costs, which are updated approximately every six months.
The SAP rating is calculated using ‘fixed costs’. This is because the SAP rating needs to be calculated using costs that are consistent between dwellings and over time, so that they can be compared more easily. Fixed costs may not correspond well with current costs in the real world; they are intended to reflect the general differences between the cost of fuel types.
The costs you see on an EPC are calculated using EPC costs, to ensure that you see the most up to date version of the fuel prices.
Fuel prices in RdSAP work on the same principles as in SAP but using a different version of Table 12 (Table 32 in RdSAP methodology). These alternative fuel prices are used in RdSAP to maintain EPC score consistency in the existing housing stock, as updating these prices would have resulted in significant changes to the EPC score of many existing dwellings.
The EPC fuel prices are calculated using a rolling 3-year average and updated every six months, whereas the Table 12 prices are updated only for new versions of the SAP methodology.
PV diverter related
PV diverters are devices used with solar photovoltaic (PV) systems to redirect surplus electricity, that would otherwise be exported to the grid, into useful loads within a property, most commonly water heating.
PV diverters are recognised in SAP by increasing PV self‑consumption and offsetting some domestic hot water demand, subject to eligibility conditions and a storage‑loss correction factor of 0.9.
The eligibility conditions for PV diverter recognition are:
- Solar PV system present and connected
- Hot water cylinder present
- Cylinder volume greater than calculated daily hot water demand
- No solar thermal system present
- No electrical battery storage present
If any of the above conditions is not met, the diverter is ignored in the SAP calculation.
EPCs
An EPC (Energy Performance Certificate) is an official document that reports the relative energy‑efficiency of a building and gives recommendations on how to improve that performance. In the UK, EPCs are required by law when a property is built, sold, or rented.
An EPC provides an Energy Efficiency Rating (EER), an Environmental Impact Rating (EIR), and improvement recommendations. EERs are given on a scale from A (most efficient) to G (least efficient) based on modelled energy use. EIRs are also given on an A-G scale, reflecting carbon emissions associated with the building’s energy use. Improvement measures are a list of possible measures that could be taken to improve energy efficiency in the building. Improvement measures in an EPC include a description of the measure, an indicative capital cost, and a potential rating improvement.
The government consulted on proposed EPC reforms in 2024-2025: Reforms to the Energy Performance of Buildings regime - GOV.UK
The most important factors that can result in a poor EPC score are poor thermal fabric, inefficient heating and/or hot water systems, and a lack of renewable energy generation, such as solar PV. Other factors, such as inefficient lighting can impact EPC scores, but these impacts tend to be relatively minor.
Poor thermal fabric leads to increased heat loss from the dwelling. Some examples of poor thermal fabric are uninsulated lofts, solid walls with no insulation, uninsulated cavity walls, and single glazed windows.
Inefficient heating and hot water systems increase energy demand for heating. Inefficient heating systems such as non-condensing gas boilers or electric immersion water heaters, with no heating controls, will score badly compared to more efficient systems, such as heat pumps, with proper controls (thermostats, programmer/time controls, etc.).
Onsite renewable energy generation, such as rooftop solar (PV or thermal) can significantly improve an EPC score by reducing total fuel costs. Renewable generation will also improve environmental impact ratings.
The role of an EPC is to provide a consistent, modelled, legally enforceable measure of a building’s energy performance to support market transparency, regulation, and national energy policy.
The most visible role of an EPC is consumer information. An EPC allows a prospective buyer or tenant to compare the energy efficiency of different properties and gain some insight into what the running costs heating demand will be. This helps create transparency in the property market.
EPCs are also used to enable regulation and enforcement. EPC underpin a number of other policy areas such as the implementing Minimum Energy Efficiency Standards (MEES) and are used to determine if a property can be legally let.
EPCs act as the common metric for building energy performance across the UK, allowing for analyses of the housing stock, such as comparison across regions, comparison across property types, and tracking improvements of the building stock over time.
Domestic EPCs lodged to the register can be retrieved here.
Improvement measures
Improvement measures are the recommended actions listed on an Energy Performance Certificate (EPC) to improve energy efficiency of a building. They show what changes can be made to improve the EPC rating, reduce energy bills, and lower carbon emissions.
Domestic Energy Assessor (DEA) Queries
For questions about approved SAP or RdSAP software provided by an accreditation scheme, the correct point of contact is the accreditation scheme’s technical support team. Each scheme operates dedicated support channels for queries about software functionality, lodgement issues, evidence requirements, and methodology updates. BRE does not provide end‑user support. BRE tests and approves SAP/RdSAP software on behalf of DESNZ but does not assist with operational queries or assessor‑level issues with the tools themselves.
If a relevant query cannot be resolved by the assessor scheme, it will be escalated to BRE for a response. Some issues that are reported may result in additional guidance being issued for assessors.
Scope of SAP (compliance tool)
RdSAP2012 Vs RdSAP10
RdSAP 2012 (final version 9.94) was designed to deliver a consistent and low‑cost way of assessing existing dwellings by relying heavily on age‑band assumptions and defaults. Where construction detail or system performance could not be evidenced, the methodology assumed minimum standards typical of the dwelling’s age.
RdSAP 10, is a major methodological upgrade aimed at improving accuracy while remaining non‑invasive. It introduces more detailed data collection (for example, measured window dimensions, finer insulation thickness increments, and improved treatment of rooms in roof), updated fuel prices and carbon factors, and recognition of modern technologies such as batteries and PV diverters. A new post‑2023 age band also allows recently built or upgraded homes to be represented more realistically.
A new EPC score is often different because the methodology used to calculate it has changed. EPCs are produced using either SAP (for new dwellings) or RdSAP (for existing dwellings), and these methodologies are periodically updated. If your previous EPC was calculated under an older version (for example RdSAP 2012) and the new one uses a later version (such as RdSAP 10), the score may change. If your dwelling was previously assessed as new using SAP, it may achieve a different rating when assessed as existing using RdSAP.
Another common reason is the type of assessment and evidence available. Older EPCs often relied more heavily on broad assumptions (such as default insulation levels or glazing areas based on age), whereas newer assessments may require measured dimensions or stronger evidence. Conversely, improved evidence or better recognition of modern technologies can sometimes increase the rating.
Generally, fuel prices are revised for each edition of the SAP specification to reflect any changes in costs between editions. SAP and RdSAP 2012 used the same fuel costs. When SAP 10 was released, the fuel costs were revised significantly to reflect the changes that had happened between versions.
RdSAP 10 was developed after SAP 10 but the decision was made to use the older fuel costs from SAP 2012 to better maintain the continuity of energy ratings for existing buildings.
The role of BRE
SAP was originally created by the Building Research Establishment (BRE) in 1993 for the UK government and was based on the BRE Domestic Energy Model (BREDEM),
The Building Research Establishment (BRE) now acts as the technical curator and delivery partner for the UK Government’s domestic energy assessment methodologies: SAP (Standard Assessment Procedure) and RdSAP (Reduced Data SAP). On behalf of the Department for Energy Security and Net Zero (DESNZ), BRE authors, maintains, and updates the SAP and RdSAP specifications, ensuring the methodologies remain consistent, scientifically robust, and suitable for regulatory use. BRE does not set policy targets or carry out individual EPC assessments; its role is to provide the trusted technical framework that others use.
Within this role, BRE tests and approves third‑party SAP and RdSAP software, manages core technical infrastructure such as the Product Characteristics Database (PCDB) and Appendix Q, and defines the formal recognition routes for new technologies.
Third‑party SAP and RdSAP software is approved by the Building Research Establishment (BRE), acting on behalf of the UK government—specifically the Department for Energy Security and Net Zero (DESNZ).
Approved software and Schemes role
BRE does not carry out SAP or RdSAP energy assessments for individual dwellings and does not produce EPCs for sale, rental, or Building Regulations compliance. Energy assessments must be undertaken by appropriately qualified and accredited assessors. We do not provide advice on specific assessments undertaken by others.
Any individual or company may develop their own software based upon the SAP specification as published on the website. However, we only carry out approval on software developed specifically for lodging EPCs to the register and with an agreement with MHCLG.
Individuals or companies wishing to develop SAP or RdSAP calculation software must work within the formal approval framework managed by BRE on behalf of DESNZ and the devolved nations. Developers are required to implement the exact SAP or RdSAP specification, including all conventions, default assumptions, fuel prices, and calculation steps, with no discretionary interpretation. Once developed, the software must be submitted to BRE for independent testing and verification against official benchmark test cases before it can be approved for use in producing EPCs or Building Regulations assessments.
Complaints procedure
The first step is always to submit a complaint to the energy assessor or the organisation which they work for. Most issues (such as data entry mistakes or missing evidence) are resolved at this stage without further escalation.
If the complaint is not resolved, it must then be escalated to the assessor’s Accreditation Scheme. The scheme will carry out an independent audit or investigation of the assessment, checking compliance with SAP/RdSAP methodology and conventions. This accreditation‑level review is the formal quality‑assurance mechanism required under the Energy Performance of Buildings framework.
Only if the complaint involves systemic misconduct, enforcement, or regulatory non‑compliance does it pass beyond the accreditation scheme to the enforcement authority acting under the Energy Performance of Buildings Regulations.
Please submit any complaints via the feedback form. Please note that methodology is distinct from policy – decisions with regard to the notional building and compliance targets are set by government.
Off-grid dwellings
An off‑grid dwelling (i.e. not connected to the mains gas network and electrical grid) is assessed in the same way as any other dwelling under SAP or RdSAP, using the actual fuels and systems present rather than gas‑based defaults.
Assessors must select the standard rate electricity tariff despite the dwelling being off grid. If the dwelling is truly self-sufficient, any theoretical electricity import will be minimised. Dwellings are assessed against uniform comfort standards, and services are assumed to fulfil a standard occupant demand for the purposes of comparison in EPCs.
Assessors must correctly identify the main space heating fuel (for example electricity, heating oil, LPG, biomass, or solid fuel) and the main heating system type, selecting the appropriate fuel and system from SAP/RdSAP tables or the PCDB where applicable. SAP treats gas‑connected and off‑grid dwellings equivalently in methodology; differences in EPC outcomes arise from fuel prices, carbon factors, and system efficiencies, not from a different assessment process.
Where a dwelling has no fixed heating system or an inadequate one, SAP and RdSAP include defined conventions for assigning a notional system to ensure consistency and comparability of EPCs.
Product listing and App Q
The SAP Product Characteristics Database (PCDB) exists to provide validated, standardised performance data for specific branded building services products used within SAP calculations. In the original SAP framework, most technologies were represented using generic “type data”, suitable when housing systems were relatively uniform. As product differentiation increased -particularly for boilers, heat pumps, ventilation systems, and controls -the PCDB was introduced so SAP could use manufacturer‑specific performance values that has been independently verified. Because the structure of SAP (and therefore the PCDB) can only be formally updated when a new SAP version is released, the PCDB acts as the permanent, integrated product data store within each SAP issue, ensuring consistency, auditability, and regulatory robustness. The PCDB database webpage can be found here.
SAP Appendix Q was introduced as a bridging mechanism to allow innovative or non‑standard technologies to be recognised between SAP releases. Appendix Q provides a formal route for new technologies whose performance characteristics are not yet representable within existing SAP equations or PCDB structures. Products admitted via Appendix Q are assessed using bespoke calculation methods and independently validated test data, typically delivered through BRE‑approved spreadsheets used alongside the main SAP calculation. Appendix Q therefore prevents innovative products from being penalised simply because SAP updates occur infrequently, while maintaining methodological control and avoiding assessor discretion. The SAP Appendix Q database webpage can be found here.
It is not a mandatory requirement for manufacturers to list their products in the PCDB. Achieving PCDB listing is manufacturer‑led, not automatic, and requires independently verified performance data (e.g. EN 14825 testing) in a format compatible with SAP calculations. In many cases, products are missing simply because the manufacturer has not applied, the model is new or rebranded, or the product’s performance characteristics do not yet fit an existing SAP category.
For all product listings, the manufacturer should apply via BRE, submitting test data and supporting evidence to demonstrate how the product should be modelled in SAP. If successful, the product will be added to the PCDB. The application page can be found here.
For most technologies (i.e. gas, oil and LPG boilers, heat pumps, mechanical ventilation systems and heating controls) the application is online via the SAP PCDB Application Portal or sent via email to uk.pcdb@kiwa.com BRE (sapproductlisting@bregroup.com)for more instructions. Information on how to apply for different technologies can be found here.
The PCDB does not list infrared heaters as a separate heating technology.
They are modelled as direct-acting electric room heaters (panel, convector or radiant heaters, i.e. heater code 691) which means they have a 100% efficiency. An industry group is currently developing a test methodology to establish whether infrared heaters provide additional benefits.)
New technologies can only be included in SAP through formal recognition routes managed by BRE (on behalf of DESNZ). If a technology fits within SAP’s existing calculation structure (for example, a conventional heat pump, boiler, or MVHR unit), the manufacturer can submit independently verified test data to BRE for inclusion in the Product Characteristics Database (PCDB). Once approved, the product can be selected directly in SAP software using its unique PCDB identifier, allowing manufacturer‑specific performance data to replace SAP default values.
If the technology cannot be represented using existing SAP equations or PCDB formats, it must instead follow the SAP Appendix Q route.
Appendix Q
Appendix Q is the means whereby some technologies can be included in SAP in between major updates to the core methodology. A calculation tool outside of SAP can be used to calculate the benefit that such technology brings. This may be expressed either as energy saved for specific fuel types alongside additional energy used, or as kg/year CO2 emissions saved or emitted.
The manufacturer must submit an Appendix Q application to BRE setting out the technology, proposed energy‑saving mechanism, and why it is outside the scope of current SAP. If accepted at an initial review, BRE will define the calculation approach, evidence requirements, and testing protocols needed to quantify performance in SAP.
The manufacturer must then undertake robust testing (to BRE‑agreed methods) and fund any required scoping studies, calculation development, and validation work. BRE uses this evidence to create an Appendix Q calculation tool and list the product in the SAP Appendix Q database, allowing assessors to include it in a SAP assessment using verified performance data.
Frequently Asked Questions for Appendix Q can be found here.
HEM related
The Home Energy Model (HEM) was developed because the Standard Assessment Procedure (SAP) had reached the limits of what its underlying architecture could support. SAP was originally created in 1993 using a monthly, steady‑state calculation designed for pen‑and‑paper assessment of gas‑heated homes. Although SAP was updated many times, its core structure remained unchanged, making it increasingly unsuitable for modelling dwellings with heat pumps, energy storage, smart controls, and low‑energy homes, and limiting its ability to support net‑zero policy and modern Building Regulations.
In response, the government commissioned BRE in 2021 to develop a replacement rather than a new version of SAP, leading to the creation of the Home Energy Model. HEM is a clean‑sheet, half‑hourly simulation model, designed to reflect modern housing technologies and align with international best practice. Unlike SAP, HEM is open‑source, has a higher time resolution, and separates the core physics model from policy application through the use of ‘wrappers’ which adapt input data for the core engine. Independent quality assurance was provided by a separate expert consortium to ensure transparency, evidence‑based decisions, and robust validation throughout its development.
HEM is intended to underpin multiple policy uses, replacing SAP for Building Regulations compliance and providing the calculation engine for reformed EPCs, including a new approach to assessing existing dwellings that will supersede RdSAP.