Breadcrumb
Product Details
Book Archived

External masonry cavity walls: wall ties - installation

Publisher
BRE Archive
Author
BRE Housing Defects Prevention Unit
Format
2 pages
Subject / Keyword
Defect Action Sheet 20, DAS20, masonry, cavity walls, wall ties, installation.
Published Date
01-Feb-1983
ISBN
Defect Action Sheet 20 (Site)

THIS PUBLICATION HAS BEEN ARCHIVED.

Whilst this publication can still be purchased some of the information in it has been superseded by more recent research and standards. The BRE Group does not accept any responsibility whatsoever for any loss or damage, including - without limitation - indirect or consequential loss or damage arising from use, or loss of use, of data or profits arising out of, or in connection with, the use of this document.

Failure: instability and rain penetration of external cavity walls.

Defects: insufficient ties to comply with Standards both generally and at openings; insufficient embedment; ties pushed into 'green' mortar; ties sloped the wrong way; drips not in the centre of the cavity; mortar on ties.

Withdrawn and replaced by DAS116 in June 1988.