Whilst this publication can still be purchased some of the information in it has been superseded by more recent research and standards. The BRE Group does not accept any responsibility whatsoever for any loss or damage, including - without limitation - indirect or consequential loss or damage arising from use, or loss of use, of data or profits arising out of, or in connection with, the use of this document.
Failures: reappearance of rising damp following dpc injection
Defects: dpc injected at wrong level; insufficient fluid injected; fluid lost through cracks caused by poor drilling